FAM2210 Air Conditioning Starter
Connect to eTel FAM Series
Real-time detect air-conditioned state
Support memory function
Suppot current monitoring

Abnormal stop-start function

NO/NC alarm status

Alarm output
Suitable for small room, ATM etc.
  • Function
  • Specifications
  • Typical applications


The superior product performance, quick and easy installation settings, is widely used in small and medium-sized computer room, UPS room, the operator of outdoor base stations, banks, ATM teller machines, and other banknote between the engine rooms, such as the use of civil air-conditioned spaces with a remote control. The most economical way to solve the air-conditioning calls from Kai.

1. Main Feature

A.     When the air conditioning main power failure, and then calls, delay 3 minutes automatically open again (delay start that helps to protect the air-conditioning, to extend the air-conditioning service life).

B.     Learning and stored in air-conditioning remote controller signal, and to ensure that power outages are not lost, and ensure that the air conditioning open to the user pre-set state mode.

C.    Real-time detection of air-conditioned state, air conditioning shut down automatically re-open the case of non-power-off exception, open the air conditioning unsuccessful automatic alarm (alarm indicator lights, start sound output dry contact alarm signal

D.    Current monitoring function effectively guarantee the reliable boot, and to prevent abnormal shutdown under the air-conditioned non-power-off automatically boot.

E.     With memory function, and opened the air-conditioning and downtime mode before state power is restored.

F.     Calls power outage or abnormal shutdown from the start: When the air-conditioning failure or power outage, the air conditioner down; failure to eliminate or re-calls.

G.    Control the air conditioner to set the mode to restart without manual intervention.

H.    Unique advantages: all the logic of power-on action that can be opened to the temperature and the cooling mode the user needs.

I.      Does not need to open the air-conditioning modify the circuit, welding line, plug and play installation and simple maintenance? Does not affect other functions of the air conditioning.

J.     With alarm output function, three consecutive times to open the air conditioning fails, the output alarm signal.

2. Technical parameters

Physical Dimensions: 13.0 × 9.0 × 3.0 (cm)

Power supply: DC12V 1A

Power consumption: 6.5W

Operating temperature: -10 ℃ -60 ℃

Operating Humidity: 10% to 90% RH non-condensing

Installation: wall, flat

Weight: 0.5kg